EasyManua.ls Logo

Siemens SINUMERIK 828D PPU Series - Page 135

Siemens SINUMERIK 828D PPU Series
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rotary switch: Feed override X30 / spindle override X31
Connector designation: X30/X31
Connector type: 2 x 5-pin plug connector, according to EN 60603-13 with coding
Table 7-31 Assignment of connector X30 / X31
Pin Signal name Signal type Meaning
1 N.C. - Not assigned
2 N.C. - Not assigned
3 M V Ground
4 N.C. - Not assigned
5 P5 V 5 V supply
6 DI122.4 / DI123.4
I
Rotary override switch, position/value 16
7 DI122.3 / DI123.3 Rotary override switch, position/value 8
8 DI122.2 / DI123.2 Rotary override switch, position/value 4
9 DI122.1 / DI123.1 Rotary override switch, position/value 2
10 DI122.0 / DI123.0 Rotary override switch, position/value 1
Digital inputs X40, X41
A total of six 24 V signals can be evaluated via the X40 and X41 connectors.
9
0
0
0
;
9
N
QQN
NN
;
',
Figure 7-25 Schematic circuit diagram X40, X41
Connector designation: X40, X41
Connector type: 4-pin plug connector
Special feature: No galvanic isolation, short-circuit proof
Max. cable length: 0.6 m
Table 7-32 X40 pin assignments
Pin Signal name Type Meaning
1 DI125.2
I
24 V input 0
2 DI125.3 24 V input 1
Connectable components
7.3 MCP Interface PN
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3 135