EasyManuals Logo

Siemens SINUMERIK 828D PPU Series User Manual

Siemens SINUMERIK 828D PPU Series
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #200 background imageLoading...
Page #200 background image
Wiring analog inputs/outputs
Procedure:
1. Strip cable for analog signals.
2. Secure the stripped connection piece of the cable with the shield connection clamp.
NOTICE
Shield contact
If the analog inputs/outputs are wired, a shielded lead must be used. The shield must be
supported.
X3 pin assignment
Table 7-92 Pin assignment (standard)
Pin Signal name Signal type Meaning
1 CO1 O Channel 1 current output for PT100
2 CI1 I Channel 1 current input for PT100
3 AI1+ I Channel 1 analog input +
4 AI1- I Channel 1 analog input -
5 CO2 O Channel 2 current output for PT100
6 CI2 I Channel 2 current input for PT100
7 AI2+ I Channel 2 analog input +
8 AI2- I Channel 2 analog input -
9 AO3+ O Channel 3 current and voltage output +
10 AO3- O Channel 3 current and voltage output -
11 AO4+ O Channel 4 current and voltage output +
12 AO4- O Channel 4 current and voltage output -
The analog signal to be measured is connected to the terminals AI 1+/- and AI 2+/-. AI stands for "Analog
Input". The CO "Current Output" and CI "Current Input" terminals supply the constant current for the 4-
wire measurement of PT100 elements.
Analog inputs
The module has two analog inputs. These can optionally be assigned parameters as voltage,
current or PT100 input.
Note
The analog inputs are only enabled following the parameter assignment.
Cycle time of the analog value accumulation: 20 ms per channel
Connectable components
7.7 PP 72/48D 2/2A PN
PPU
200 Manual, 01/2014, 6FC5397-2DP40-3BA3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 828D PPU Series and is the answer not in the manual?

Siemens SINUMERIK 828D PPU Series Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 828D PPU Series
CategoryControl Unit
LanguageEnglish

Related product manuals