Connection options
The overview below shows the interfaces and their connection possibilities:
Digital input
Digital I/O
DRIVE-CLiQ
Electronic handwheel (up
to 2)
USB storage medium
USB storage medium
Ethernet cable
Programming device, PC
Remote diagnostics router
DRIVE-CLiQ cable
see MOTION-CONNECT (see Catalog NC 61)
≤ 50 m
Power supply
Article number
Pre-assembled cable
Drive:
12 digital inputs
8 digital inputs/outputs
NC:
8 digital inputs
8 digital outputs
Exclusively SINAUT
MD720-3 GSM/GPRS
modem
Factory network
≤ 30 m
≤ 10 m
≤ 100 m
Ethernet cable
≤ 100 m
24 V DC
Ethernet OP
front side
Ethernet PPU
rear side
RS232C
PLC I/O
6NH7701-5AN (length: 2.5 m)
≤ 3 m
6SL3060-4A..0-0AA0 (in fixed lengths)
6FX2002-1DC00-1..0 (precisely to the meter)
≤ 70 m
6FX8002-2BB01-1A..
≤ 3 m
USB cable
≤ 3 m
USB cable
≤ 3 m
Handwheels
USB
OP front
CF card
OP front
USB PPU rear
side
1)
Only for PPU 280.3/PPU 281.3
2)
Not for PPU 240.3/PPU 241.3
NX10.3
1)
SINAMICS S120
Terminal Module
TM54F
G_NC01_DE_00410
SINUMERIK
MCP 310C PN/
MCP 483C PN/
MCP Interface PN
SINUMERIK
I/O module
PP 72/48D PN/
PP 72/48D 2/2A PN
SIMATIC DP PN/PN
coupler
Port 1
Port 2
2)
X120
X120
X1
X127
X130
X143
X140
X125
X135
X100
X101
X102
X122
X132
X242
X252
SINUMERIK 828D
PPU 240.3/PPU 241.3
PPU 260.3/PPU 261.3
PPU 280.3/PPU 281.3
Figure 6-1 Connection options of the PPU
Interface description
6.1 Interface overview
PPU