04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–208
SINUMERIK 840C / SIMODRIVE 611–D (DA)
300753 Timer n-controller at stop wrong Reset key
Cyclic after control power up
S Controllers disabled, motor braked
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
–
Speed controller timer at stop MD 1605 must always be larger or the same as the pulse suppression cutoff speed
MD 1403.
Applies as from SW 3
300754 Signal number invalid Reset key
300854
Cyclic after control power up
for MSD:
S Pulse suppression, motor runs down
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
for FDD:
S Controllers are disabled, motor is braked
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
Response via MD 1613.0 can be configured as from drive SW 2.
Alarm output can be activated via MD 1012.4 as from V. 5.2 (611D: SW 3).
S MD 1012.4 = 0: 300754
S MD 1012.4 = 1: 300854
Signal number invalid in the variables signalling function and min-max memory.
Enter correct signal number.
Applies as from SW 4
300755 V/f operation: motor running Reset key
300855
Cyclic after control power up
for MSD:
S Pulse suppression, motor runs down
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
for FDD:
S Controllers are disabled, motor is braked
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
Response via MD 1613.0 can be configured as from drive SW 2.
Alarm output can be activated via MD 1012.4 as from V. 5.2 (611D: SW 3).
S MD 1012.4 = 0: 300755
S MD 1012.4 = 1: 300855
V/f operation: at initialization, the motor turns.
Stop the motor.
Applies as from SW 4
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms