EasyManua.ls Logo

Siemens SINUMERIK 840C - Page 217

Siemens SINUMERIK 840C
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–209
SINUMERIK 840C / SIMODRIVE 611D (DA)
300756 Hysteresis of torque setpoint smoothing too large Reset key
Cyclic after control power up
for MSD:
S Pulse suppression, motor runs down
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
for FDD:
S Controllers are disabled, motor is braked
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
Response via MD 1613.0 can be configured as from drive SW 2.
Hysteresis of the torque setpoint smoothing MD 1246 is greater than or equal to the threshold of the torque set-
point smoothing MD 1245.
Eliminate error on inputting MD 1246 and MD 1245.
Applies as from SW 4
300757 Torque matching factor too great Reset key
Cyclic after control power up
for MSD:
S Pulse suppression, motor runs down
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
for FDD:
S Controllers are disabled, motor is braked
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
Response via MD 1613.0 can be configured as from drive SW 2.
The torque matching factor MD 1191 is beyond the format limit.
Eliminate error on inputting MD 1191.
Applies as from SW 4
300758 Upper generator threshold too high Reset key
300858
Cyclic after control power up
for MSD:
S Pulse suppression, motor runs down
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
for FDD:
S Controllers are disabled, motor is braked
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
Response via MD 1613.0 can be configured as from drive SW 2.
Alarm output can be activated via MD 1012.4 as from V. 5.2 (611D: SW 3).
S MD 1012.4 = 0: 300758
S MD 1012.4 = 1: 300858
Upper threshold of the two-point controller is too high in the generator mode i.e. the sum of the values in
MD1631 + MD1632 exceeds that in MD1633.
Eliminate error on inputting MD 1631, MD 1632 and MD 1633.
Applies as from SW 4
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description
07/97

Table of Contents