04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–45
SINUMERIK 840C / SIMODRIVE 611–D (DA)
3007 Error in programming setting data Acknowledgement key
When executing a part program
S Machining stops
S M19 without S word
S Spindle not present
S Illegal setting data programmed,
e.g. G92 X... Y..., G92 D, T, A, I, J
S Error in parameterization of handwheel pulse weighting for G27 (SD 564*)
S Check the faulty block in the “Correction block” display
S If possible the cursor is positioned in front of the faulty word
S The number of the faulty block is after the alarm number in the alarm line
Alarm is displayed with reference to block and channel
3008 Subroutine error Acknowledgement key
When executing a part program
S Machining stops
S M17 not in the subroutine
S M02, M30 in the subroutine
S M17 in the main program
S More than 8 subroutine levels
S Check the faulty block in the “Correction block” display
S If possible the cursor is positioned in front of the faulty word
S The number of the faulty block is after the alarm number in the alarm line
S SW 3 and higher, number of permissible subroutine levels exceeded
S Subroutine call in the block with M2, M30 or M17
S From SW 5 subroutines and main programs can be terminated with M02, M17 and M30.
Alarm is displayed with reference to block and channel
3009 Program disabled Acknowledgement key
S On NC START, or when editing a program during machining
S Machining stops
S Pressing “NC START” calls a program which was disabled by being opened, by “Copy” or by “Rename”. While
a program is being edited it may not be called by “NC START”.
Once editing is complete, the locked program must be enabled.
Alarm is displayed with reference to block and channel
3010 Intersection error Acknowledgement key
S When executing a part program
S Machining stops
A mistake has been discovered during reference processing in conjunction with the calculation of intersection.
Possible causes are:
S Contour program without G00, G01, G03
S Contour program with “Empty buffer memory” (@714)
S Programmed axes are not the same as the plane selected
S No intersection found
S Stock removal path circular
S R parameter number not available
Check program in which contour is stored.
Alarm is displayed with reference to block and channel
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description
01/99