04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–52
SINUMERIK 840C / SIMODRIVE 611D (DA)
3044 Error: NCK display update to MMC Acknowledgement key
S Cyclic
S No dynamic display parts are displayed
An error has occurred during transmission of dynamic display parts such as variable values/texts from the NCK to
MMC.
Activate notebook for I code and send message together with notebook entry to
System Support (system program change required)
3045 Error: NCK fixed graphics to MMC Acknowledgement key
S On selecting the display
S Not all fixed graphics parts of the display description are shown on the screen
An error has occurred during transmission of the graphics part of the display from NCK to MMC.
Activate notebook for I code and send message together with notebook entry to
System Support (system program change required)
3046 Faulty variable Acknowledgement key
as from SW 5.4: POWER ON
S On selecting the display
S Not all variable values/texts are displayed
In the display description, a variable text has been programmed without an end identifier because of an error in
the NC workstation software. This produces a transfer format error.
S Check NC workstation
The error must be at the point of interruption of the subsequent elements which are no longer displayed.
3047 Read data selector from harddisk Acknowledgement key
as from SW 5.4: POWER ON
S Cyclic if there is no response from the MMC approximately 5 seconds after the harddisk has requested the
data selector.
The data selector does not switch over to the disk directory.
There is no response from the MMC to the request for the data selector from the harddisk.
Switch the control off and then on again.
3061 Processing sections cannot be loaded Acknowledgement key
When processing a program with execution from external in AUTOMATIC while reloading a section
Processing stops
The program section which is to be read in no longer fits in the circular buffer for execution from external
The program can be continued with NC START although processing may be interrupted when the program is re-
loaded.
Increase the size of the circular buffer for execution from external
Applies to SW 2 only
3072 Alarm text not available Acknowledgement key
S If an alarm occurs without alarm text
S None
S When generating cycles, alarms have been provided for which no text was programmed
S NC alarms which are not provided with a text in the system have been triggered
Look at the complete listing of alarm displays and check off alarm numbers without text.
With cycle alarms, program an appropriate text.
With system alarms, notify your Systems Support.
Applies to SW 1 only
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description

Table of Contents

Other manuals for Siemens SINUMERIK 840C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840C and is the answer not in the manual?

Siemens SINUMERIK 840C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840C
CategoryControl Unit
LanguageEnglish

Related product manuals