04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–69
SINUMERIK 840C / SIMODRIVE 611–D (DA)
1196* Reconfiguration not allowed Acknowledgement key
When RECONFIGURING with G function (G401), i.e. when adding, removing a leading axis or changing the link
structure or on CLEAR configuration (from NCK)
Interlocking of NC START
“Reconfiguration allowed” is not set (MD 1844, bit 1)
Correct input, set MD bit
Applies as from SW 3
1200* Division wrong POWER ON
S
Cyclic
S Interlocking of NC START
S Machining is interrupted
The “Division from PLC” function is not possible because:
S NC machine data “Number of divisions” has an invalid value
S NC machine data “Absolute division increment” has an invalid value
S NC machine data “Division offset” has an invalid value
S Indexing axis has been defined as a rounding axis, which is impermissible.
S Check and correct the relevant machine data.
1204* Traversing range limits exceeded Reset key
S Cyclic (only with linear axes)
S Interlocking of NC START
S Machining is interrupted
S Set value 0 (abrupt, no deceleration ramp)
If no software limit switches or working area limitations are active, it is theoretically possible to exceed the
maximum possible traversing range (set by the combination of axis-specific position control resolution and input
resolution). As this would lead to traversing errors, however, the traversing range limit is monitored and, when it is
exceeded, alarm 1204* is set.
Traverse back into the permissible range in the opposite direction using INC or JOG mode.
1208* Link factor KF not allowed Acknowledgement key
When entering a new link factor via the G function (from NCK).
Command is not executed, the previous link factor is maintained. Interlocking of NC start.
Denominator J=0 is programmed, link factor incorrectly programmed, following axis not programmed.
Correct link factor
Applies as from SW 3
1212* Overwriting of pos. not allowed Acknowledgement key
When programming a position with GI command.
G command is not executed: interlocking of NC START
GI positions must not be overwritten (enabled with MD 1844 *, bit 3)
Correct input
Applies as from SW 3
1216* Reconfiguration/deletion not allowed Reset key
When RECONFIGURING with G function (G401), i.e. when a leading axis is added or removed or when the link
structure is altered or on DELETE CONFIGURATION (from NCK)
Interlocking of NC START, NC STOP, i.e. channel is stopped: command is not executed: JOG mode still possible.
RECONFIGURATION or DELETE CONFIGURATION is not possible until LINK OFF has been set.
RECONFIGURATION is only possible after DELETE CONFIGURATION. Program a new configuration block
(G401); following axis already exists.
First set LINK OFF for the GI grouping in question.
Applies as from SW 3
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description