EasyManuals Logo

Siemens SINUMERIK 840C Diagnostics Guide

Siemens SINUMERIK 840C
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–70
SINUMERIK 840C / SIMODRIVE 611D (DA)
1220* GI configuration not allowed Acknowledgement key
When programming DEFINE CONFIGURATION with G function. (From NCK)
Command is not executed. Interlocking of NC START
Possible causes:
S Do leading and following axes have a position measuring system (encoders)?
S Is the following axis linked to itself as a leading axis?
S Can the axis be a following axis (MD 1844*)?
S Link structure switchover not permissible (MD 1844*)
S Link type for the LA/LS not allowed (MD 1456*/496*)?
S The following axes must always be real available axes, i.e. a measuring circuit (POS encoder) must be defi-
ned. A measuring circuit must be defined for leading axes/spindles with link structure K2 (actual position link).
S Leading axes/spindles and following axis are not in the same mode group.
S Not exactly one leading spindle defined for following spindle.
S One of the axes in the GI grouping is a fictitious transformation axis.
S No synchronous positions have been defined for on-the-fly synchronization.
Check configuration
Applies as from SW 3
1224* Change of KF not allowed Acknowledgement key
When a new link factor is entered via G function (from NCK).
The command is not executed, the previous link factor is kept.
Interlocking of NC START
The link factor default setting must not be changed (MD 1844*).
Change default setting if necessary.
Applies as from SW 3
1228* Link factor KF not allowed Reset key
When entering a new link factor via G function (from NCK).
Command is not executed, the previous link factor remains. Interlocking of NC START; NC STOP. Channel stop;
JOG mode still possible.
The entered link factor does not lie within the range 0.00000001 <= /KF/ <= 10.000000 or denominator J = 0 or the
individual values are so high that internal overflows are the result.
Correct or shorten link factor KF
Applies as from SW 3
1232* Change of link factor KF not allowed Reset key
When entering a new link factor via G function (from NCK).
Command is not executed, the previous link factor remains. Interlocking of NC START; NC STOP. Channel stop;
JOG mode still possible.
The link factor default setting must not be changed (MD 1844*).
Change default setting if necessary.
Applies as from SW 3
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description

Table of Contents

Other manuals for Siemens SINUMERIK 840C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840C and is the answer not in the manual?

Siemens SINUMERIK 840C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840C
CategoryControl Unit
LanguageEnglish

Related product manuals