EasyManuals Logo

Siemens SINUMERIK 840C Diagnostics Guide

Siemens SINUMERIK 840C
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #89 background imageLoading...
Page #89 background image
04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–81
SINUMERIK 840C / SIMODRIVE 611D (DA)
1372* Protection zone collision minus RESET
Cyclic with active function Collision monitoring
Axis number
Machining standstill;
disabling of NC Start
Overlap of two protection zones has been recognized
Travel free and trigger mode group reset
Applies as from SW 6.
1376* Check absolute value encoder position Cancel key
S Loading of complete NC MD files
S Absolute value encoder available and range expansion of Endat absolute value encoder parameterized
None
Startup, whjich is to be performed by loading an NC MD file, has possibly not yet been terminated on an axis with
absolute value encoder. The startup engineer must then decide whether further startup steps have to be carried
out. This alarm remains present even after Power Off.
S Bring axes to closedloop control mode (terminate possible initial clear mode) and check the actual postion
displayed.
S If the actual postion is not correct (e.g. after loss of data in SRAM through hardware replacement), startup
steps must be carried out.
S Acknowledge alarm (not possible in initial clear mode!)
2000* LEC grid spacing illegal POWER ON
Cyclic
Removal of NC START
In the case of the spindle (e.g. synchronous spindle mode), a modulo value has been entered for the axis concer-
ned which cannot be divided exactly into 360°, which means that the grid spacing is not equal.
Check NC MD* 3440*
Applies as from SW 3
2001* Speed setpoint warning limit responded Reset key
Cyclic
Interlocking of NC START
S The setpoint on the DAC is higher than entered in NC MD 268* Max. speed setpoint (DAC). It is not possible
to increase the setpoint any further.
The alarm 2001* Speed setpoint warning limit can occur when an M19 positioning is requested while the
drive unit is not ready (e.g. setpoint cable break: actuator switched off; actuator not enabled by PLC).
S An incorrect feedback polarity has been parameterized in the spindle positioning mode (sign error).
S Traverse at slower speed
S Check the actual values (encoder)
S Check NC MD Max. speed setpoint (DAC)
S Check the drive actuator
Scan
Parameters
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
1 Alarms
1.5.1 Alarm description
07/97

Table of Contents

Other manuals for Siemens SINUMERIK 840C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840C and is the answer not in the manual?

Siemens SINUMERIK 840C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840C
CategoryControl Unit
LanguageEnglish

Related product manuals