6537 27-2 Undervoltage picked up
(27-2 picked up)
27/59 O/U Volt. OUT * On
Off
* LED BO 74 37 2 Yes
6538 27-2 Undervoltage PICKUP
w/curr. superv (27-2 PU CS)
27/59 O/U Volt. OUT * On
Off
* LED BO 74 38 2 Yes
6539 27-1 Undervoltage TRIP (27-1
TRIP)
27/59 O/U Volt. OUT * on m LED BO 74 39 2 Yes
6540 27-2 Undervoltage TRIP (27-2
TRIP)
27/59 O/U Volt. OUT * on * LED BO 74 40 2 Yes
6565 59 Overvoltage protection
switched OFF (59 OFF)
27/59 O/U Volt. OUT On
Off
**LEDBO74651Yes
6566 59 Overvoltage protection is
BLOCKED (59 BLOCKED)
27/59 O/U Volt. OUT On
Off
On
Off
* LED BO 74 66 1 Yes
6567 59 Overvoltage protection is
ACTIVE (59 ACTIVE)
27/59 O/U Volt. OUT On
Off
**LEDBO74671Yes
6568 59-1 Overvoltage V> picked up
(59-1 picked up)
27/59 O/U Volt. OUT * On
Off
* LED BO 74 68 2 Yes
6570 59-1 Overvoltage V> TRIP (59-1
TRIP)
27/59 O/U Volt. OUT * on m LED BO 74 70 2 Yes
6571 59-2 Overvoltage V>> picked up
(59-2 picked up)
27/59 O/U Volt. OUT * On
Off
* LED BO
6573 59-2 Overvoltage V>> TRIP (59-2
TRIP)
27/59 O/U Volt. OUT * on * LED BO
6851 >BLOCK 74TC (>BLOCK 74TC) 74TC TripCirc. SP * * * LED BI BO
6852 >74TC Trip circuit superv.: trip
relay (>74TC trip rel.)
74TC TripCirc. SP On
Off
* * LED BI BO 170 51 1 Yes
6853 >74TC Trip circuit superv.: bkr
relay (>74TC brk rel.)
74TC TripCirc. SP On
Off
* * LED BI BO 170 52 1 Yes
6861 74TC Trip circuit supervision OFF
(74TC OFF)
74TC TripCirc. OUT On
Off
* * LED BO 170 53 1 Yes
6862 74TC Trip circuit supervision is
BLOCKED (74TC BLOCKED)
74TC TripCirc. OUT On
Off
On
Off
* LED BO 153 16 1 Yes
6863 74TC Trip circuit supervision is
ACTIVE (74TC ACTIVE)
74TC TripCirc. OUT On
Off
* * LED BO 153 17 1 Yes
6864 74TC blocked. Bin. input is not
set (74TC ProgFail)
74TC TripCirc. OUT On
Off
* * LED BO 170 54 1 Yes
6865 74TC Failure Trip Circuit (74TC
Trip cir.)
74TC TripCirc. OUT On
Off
* * LED BO 170 55 1 Yes
10080 Error Extension I/O (Error Ext I/O) Device, General OUT On
Off
**LEDBO
10081 Error Ethernet (Error Ethernet) Device, General OUT On
Off
**LEDBO
10083 Error Basic I/O (Error Basic I/O) Device, General OUT On
Off
**LEDBO
17330 >Load restoration Block (>LR
Block)
Load Restore SP On
Off
**LEDBIFC
TN
BO
17331 >Load restoration break (>LR
Break)
Load Restore SP On
Off
**LEDBIFC
TN
BO
17332 >Load restoration Process (>LR
Process)
Load Restore SP * * * LED BI FC
TN
BO
17333 >Load restoration Reset (>LR
Reset)
Load Restore SP On
Off
**LEDBIFC
TN
BO
17334 Load restoration is OFF (LR OFF) Load Restore OUT On
Off
On
Off
* LED BO
17335 Load restoration successful (LR
Successful)
Load Restore OUT On
Off
On
Off
* LED BO
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7RW80 and is the answer not in the manual?

Siemens SIPROTEC 7RW80 Specifications

General IconGeneral
BrandSiemens
ModelSIPROTEC 7RW80
CategoryRelays
LanguageEnglish

Related product manuals