Technical data
11.4 Cable data
SITRANS F M MAG 5000/6000
68 Operating Instructions, 01/2010, SFIDK.PS.026.G1.02
11.4 Cable data
Description
Cable for standard electrode or coil
Electrode cable, double shielded
Cable kit with standard coil cable and electrode cable double
shielded (also available as low noise cable for MAG 1100
sensor )
Technical data
Standard electrode
cable
(electrode/coil)
Special cable
(electrode)
No. of conductors 3 3
Sqr. area 1.5 mm
2
0.25 mm
2
Screen Yes Double
Color code Brown, blue, black Brown, blue, black
Outside color Grey Grey
Ext. diameter 7.8 mm 8.1 mm
Conductor Flexible CU Flexible CU
Basic data
Isolation material PVC PVC
Flexible installation -5 ... +70°C
(23 ... 158°F)
-5 ... +70°C
(23 ... 158°F)
Ambient temperature
Non-flexible installtaion -30 ... +70°C
(-22 ... 158°F)
-30 ... +70°C
(-22 ... 158°F)
Capacity 161.50 pF/m N/A
Inductance 0.583 μH/m N/A
Cable parameter
L/R 43.83 þH/Ω N/A
11.5 Cable requirements
Coil
cable
Electrode
cable
No. of conductors 2 3
Min. sqr. area 0.5 mm
2
0.2 mm
2
Screen Yes Yes
Basic data
Max. capacitance N/A 350 pF/m
Media temperature:
< 100 °C 40 Ω N/A
Max. cable loop resistance
> 200 °C 6 Ω N/A
M20x1.5 gland - Cable ø 5 ... 13 mm (0.20 ... 0.51 inches) Cable glands on sensor and
transmitter