Additional Installation Instructions
B.3 Magnetic mounting
FSS200 clamp-on sensors
Installation Manual, 08/2017, A5E36255466-AC
105
3. Determine which sensor type will be installed into the magnetic mounting frame.
Note
C and D-size FSS200 Universal sensor mounting
To mount C or D
-size FSS200 Universal sensors the spacer plates must be attached to
the side panels of the mounting frames. The Clamp Plate Assembly has to be place in the
C
-ALL slot for C-size FSS200 Universal sensors and in the D-ALL slot for D-size FSS2
00
Universal sensors. Refer to figure for spacer plate locations and figures below for Clamp
Plate slot and optional Clamp
-on mounting strap slot locations.
Figure B-13 Sensor clamp plate assembly location
Insert Clamp Plate assembly in the C-ALL slot for C-
size FSS200 Universal and Hi Precision
sensors.
Insert Clamp Plate assembly in the D-ALL/UNI-E slot for D-size FSS200 Hi Precision, Uni-
versal and E-size FSS200 Universal sensors.
Slots for optional clamp-on mounting straps.
4. Check to ensure that you have a matched set of sensors. They both should have the
same serial number but marked with either an "A" or "B" (e.g., 100A and 100B).
5. The sensor selection will determine which Spacer Bar mounting frame holes will be used
when attaching the spacer bar. Refer to the table below for selecting the appropriate
spacer bar sensor positioning hole.
For C-size FSS200 Universal or C-size FSS200
Hi Precision sensors
Select hole marked
C UNIV / C HP
For D-size FSS200 Universal and E-size
FSS200 Universal sensors
Select hole marked
D UNIV / E UNIV
For D-size FSS200 Hi Precision sensors
Select hole marked D HP