Connecting
5.5 Connecting sensors to transmitter
FSS200 clamp-on sensors
Installation Manual, 08/2017, A5E36255466-AC
65
Transmitter FST020
Preparing for the connection
1. Loosen the six lid screws.
2. Open the lid.
Connecting the flow sensor cables
For the system to function properly, the sensor cables must be connected correctly. The
sensor cables should be connected as upstream 1A and downstream 1B.
The sensor cables are delivered with a premounted F-connector at the transmitter end.
1. Remove the sensor blind plug from wall mount housing.
2. Feed the unterminated end of the cables through the two holes in the gland until 100mm
of cable with the F-connector is remaining.
3. Feed the the cables though the hole in the transmitter case and then through the gland
nut.
4. Screw the cable end into the right-angle F-connector (supplied with the transmitter).