Installing/mounting
4.6 Installation instructions
FSS200 clamp-on sensors
30 Installation Manual, 08/2017, A5E36255466-AC
Wizard sensor setup procedure
Referring to the Operation Instuction manual for your transmitter, use the Wizard sensor
setup procedure to set up the clamp-on sensors for your unit.
Installing sensors in Reflect mount
Reflect mount - Sensor installation using mounting frames and spacer bar
1.
Use the Wizard setup procedure to program the transmitter for the sensors that were
selected.
2. After receiving the spacing number index from the transmitter, make a note of the number
displayed then prepare the pipe surface area where the sensors will be mounted.
Before continuing refer to the Reflect mount installation diagram example below.
Spacer bar pin and reference hole
7ME39600*** Mounting Frame
Larger pipes may need additional mount-
Spring Clip (not present on some mounting
Orientation for Single path sensor at the 9
Spacer bar
Orientation for Dual path sensor at the 10
Figure 4-6 Reflect mount