FSS200 clamp-on sensors
Installation Manual, 08/2017, A5E36255466-AC
81
Technical data
7
7.1
Sensor specifications
Note
Based on pipe wall t
hickness (steel pipes only)
Note
All sensors are stainless steel construction.
Table 7- 1 Hi Precision sensors
Sensor Size
Pipe wall (mm)
Pipe wall (inch)
Pipe wall
min.
max.
min.
max.
A1H
0.64
1.02
0.25
0.04
A2H
1.02
1.52
0.04
0.06
A3H
1.52
2.03
0.06
0.08
B1H
2.03
3.05
0.08
0.12
B2H
3.05
4.06
0.12
0.16
B3H
2.7
3.3
0.106
0.128
C1H
4.06
5.84
0.16
0.23
C2H
5.84
8.13
0.23
0.32
D1H
8.13
11.18
0.32
0.44
D2H
11.18
15.75
0.44
0.62
D3H
7.4
9.0
0.293
0.354
D4H
15.75
31.75
0.62
1.25

Table of Contents