Additional Installation Instructions
B.4 Hi Precision mount
FSS200 clamp-on sensors
130 Installation Manual, 08/2017, A5E36255466-AC
Figure B-45 Hi Precision mount Direct mode Dual enclosure (for minimum index spacing)
B.4.4.2
Positioning strap retainers and straps
Installation procedure
Straps should be cut to length and installed with strap retainers on the pipe.
1. Roughly position the strap retainers on the horizontal plane of the pipe with the strap
fastener located at the top of pipe.
2. Using the provided Mylar material, make a template by wrapping the Mylar strip around
the pipe and overlap the ends.
Overlap edge
Spacing guide
Mark (or fold) exactly at halfway point
Circumference
Figure B-46 Finding the halfway distance
3. Tape the ends together. Mark the Mylar template where the ends overlap with a marker.
4. Remove the template from the pipe.
5. Align the mark with the other end of the Mylar strip and then fold the Mylar strip keeping
the ends aligned.
6. Using a marker, mark the fold crease.