Additional Installation Instructions
B.3 Magnetic mounting
FSS200 clamp-on sensors
Installation Manual, 08/2017, A5E36255466-AC
107
7. Carefully place the frame assembly on the cleaned pipe location. Ensure that the frame
assembly is straight along the pipe axis.
8. Temporary insert a sensor into the frame assembly and push it up to the frame stop.
Figure B-16 Finding the second frame location
Measure from front of sensor
Horizontal pipe axis
Approximate location of second frame and sensor assembly
9. With a measuring tape, measure the length of the Ltn from the inside edge of the sensor
to an approximate location for the second frame assembly.
Figure B-17 Finding the second frame location
Measure from front of sensor
Horizontal pipe axis
Approximate location of second frame and sensor assembly
10.Carefully place the second frame assembly on the pipe in the approximate location and
align it with the axis of the pipe.
11.With a pencil or marker, mark a generous area of 13 mm (1/2") all around the frame.
Remove the frame assembly.
12.Prepare the area you marked by de-greasing surface, if needed, and by removing any
grit, corrosion, rust, loose paint or surface irregularities with the abrasive material
provided.