Connecting
5.4 Sensor wiring
FSS200 clamp-on sensors
54 Installation Manual, 08/2017, A5E36255466-AC
Figure 5-3 Triaxial ground wire clamp parts
Ground wire clamp assembly
1. Take the prepared sensor cable end and fill the F-connector with Super Lube coupling
compound, then screw it onto the sensor
① and hand tighten.
2. Coat the NPT Adapter
⑮ with Super Lube coupling compound, screw it onto the sensor
⑧ and hand tighten.
3. Screw the cable gland body hex
⑭ into the NPT Adapter. Tighten the gland body hex
until it butts up against the NPT Adapter end (approx. 8Nm).
4. Using an adjustable wrench, screw on the gland cap nut
⑨ and tighten to obtain
optimum sealing. The gasket
⑪ must protrude along the cable as shown.
5. Form the Earth clamp
⑥ around the gland cap nut ⑨ as shown.