Connecting
5.4 Sensor wiring
FSS200 clamp-on sensors
54 Installation Manual, 08/2017, A5E36255466-AC
Label
Instruction sheet
Plastic bag
Earth clamp
Screw - ISO 7045
U-clamp
Spring washer DIN 127B
Figure 5-3 Triaxial ground wire clamp parts
Ground wire clamp assembly
1. Take the prepared sensor cable end and fill the F-connector with Super Lube coupling
compound, then screw it onto the sensor
and hand tighten.
2. Coat the NPT Adapter
with Super Lube coupling compound, screw it onto the sensor
and hand tighten.
3. Screw the cable gland body hex
into the NPT Adapter. Tighten the gland body hex
until it butts up against the NPT Adapter end (approx. 8Nm).
4. Using an adjustable wrench, screw on the gland cap nut
and tighten to obtain
optimum sealing. The gasket
must protrude along the cable as shown.
5. Form the Earth clamp
around the gland cap nut as shown.