Additional Installation Instructions
B.2 Mounting tracks for Size A and B sensors
FSS200 clamp-on sensors
Installation Manual, 08/2017, A5E36255466-AC
97
The Direct mount configuration uses a set of two track rail assemblies; one for each sensor,
installed 180° apart on the pipe. The set includes:
Reflect mode track assembly - This track rail includes the tension screw and REF hole to
position one sensor.
Direct mode track assembly - This track rail has number index holes for inserting an index
pin to position the other sensor.
Note
A pin will be inserted into the hole designated by the number index on the Direct mode
track rail to position one of the sensors (see
in figure below).
To SITRANS FST030 transmitter
7ME3950 series sensor downstream
7ME39600CK series cable
Flow direction
Mounting strap guide
7ME39600M series mounting track
Sensor clamp
REF hole index pin
7ME3950 series sensor upstream
Couplant compound
7ME39600M series mounting track
Pipe
Figure B-7 Direct Mount 180° opposed with Mounting Tracks