INSTALLATION 3
25
SITRANS FX300
www.siemens.com/flow06/2009 - SFIDK.PS.050.F2.02 A5E02100423
3.4.7 Heat insulation
CAUTION!
The area above the converter support must not be heat-insulated.
The heat insulation 3 may only extend to the maximum height 1 shown below up to the
connecting screws of the measuring sensor.
Figure 3-7: Heat insulation on connection piece and signal cable
1 Max. height of insulation up to intermediate piece between measuring sensor and signal converter
2 Max. thickness of the insulation up to the bend of the pressure pipe
3 Insulation
CAUTION!
The heat insulation 3 may only extend as far as the bend of the pressure sensing line 2.