EasyManua.ls Logo

Siemens SITRANS FX300 - Page 76

Siemens SITRANS FX300
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 TECHNICAL DATA
76
SITRANS FX300
www.siemens.com/flow 06/2009 - SFIDK.PS.050.F2.02 A5E02100423
Flow rate limits
Product Nominal sizes Minimum flow rates Maximum flow rates
EN ASME [m/s] [ft/s] [m/s] [ft/s]
Liquids DN15300 ½…12"
0.5x(998/ρ)
0.5
1
1.64x(998/ρ)0.5 2
7x(998/ρ)
0.47
1
23x(998/ρ)0.47 2
Gas, steam DN15300 ½…12"
6x(1.29/ρ)
0.5
3
16.4x(1.29/ρ)0.5
4
7x(998/ρ)
0.47
3
23x(998/ρ)0.47 4
ρ = operating density [kg/m
3
]
1 Minimum flow rate 0.3 m/s - maximum flow rate 7 m/s
2 Minimum flow rate 0.984 ft/s - maximum flow rate 23 ft/s
3 Minimum flow rate 2 m/s - maximum flow rate 80 m/s; DN15 up to 45 m/s and DN25 up to 70 m/s
4 Minimum flow rate 6.6 ft/s - maximum flow rate 262 ft/s; DN15 up to 148 ft/s and DN25 up to 230 ft/s
MA_Siemens_Sitrans_FX300_R02_en_PRT.book Page 76 Monday, June 22, 2009 8:17 AM