Enhancement Parameters
P733 (G) SCROLL ACCESS
Use this feature to select the programming mode parameter scroll access option
desired.
Select: "off" to scroll access all operator accessible parameters (P000 to
P999).
"smart" to scroll access Quick Start, previously altered, and tagged
parameters.
"tagged" to scroll access operator tagged parameters only.
If SmartLinx module is installed, the applicable protocol specific parameters
(P750 - P789) are preset as tagged.
(Any accessed parameter may be
tagged
or
untagged
by pressing ).
is displayed when a previously tagged or altered parameter is accessed.
values: 0 = off
1 = smart (preset)
2 = tagged
P734 (G) SCANNING INDICATORS
Use this feature to have the Scan Point indicators display the Point Numbers
currently "on priority" (see SMART SCAN, P720). As preset, the Point Number
being scanned is displayed.
values: 1 = Point Number being scanned
2 = Point Numbers on priority
P740 PERIPHERAL COMMUNICATIONS
Use this feature to select the ASCII message format used in Siemens
Milltronics proprietary communications loop.
Select: "off" if peripherals are not used (increases the SITRANS LU10
processing speed).
"normal" to have messages transmitted in a continuous string of
characters (requires less SITRANS LU10 processing time
than formatted messages).
"formatted" to have commas inserted between the message fields (for
easier message recognition e.g. when viewed on a
monitor).
Refer to Technical Reference BIC-II Support if a BIC-II is used.
Refer to Technical Reference BIC-II Support if a BIC-II is used.Refer to Technical Reference BIC-II Support if a BIC-II is used.
Refer to Technical Reference BIC-II Support if a BIC-II is used.
values: 0 = off
1 = normal (preset)
2 = formatted messages