7ML19985AN02 SITRANS LU10 – INSTRUCTION MANUAL Page 59
mmmmm
Enhancement Parameters
Display Parameters (P730 to P734, P740)
P730 (G) AUXILIARY READING
Use this feature to display operator selected Auxiliary Readings temporarily.
Select "OFF" to display Auxiliary Readings temporarily. Select "HOLd" to display
Auxiliary Readings until another Auxiliary Reading is selected.
(See
Operation
Keypad for RUN mode Auxiliary Reading selection.)
To select the Auxiliary Reading operation desired:
1. Press to display the Auxiliary Function symbol.
2. Press or to display the "OFF" or "HOLd" (preset) option as desired.
3. Press .
If desired, also enter the Parameter Number to default in the Auxiliary Reading
display.
values: 000 to 999
P731 (G) AUXILIARY READING KEY
Use this feature to enable a specific Parameter Value to be monitored in the
RUN mode.
Enter the Parameter Number whose value is to be displayed in the Auxiliary
Reading field when is pressed in the RUN mode.
(See
Operation
Keypad for RUN mode Auxiliary Reading selection.)
values: 000 to 999 (preset to (P921) Material Reading)
P732 (G) DISPLAY DELAY
Use this feature if the Point Number display scrolls too quickly in the RUN mode.
Enter the delay (in seconds) before the display advances to the next Point
Number.
(Point Number display scrolling is independent from transducer scanning.)
values: 0.5 to 10 (preset to 1.5 seconds)