7ML19985AN02 SITRANS LU10 – INSTRUCTION MANUAL Page 53
mmmmm
Enhancement Parameters
Rate Parameters (P700 to P707)
P700 MAX FILL RATE
Adjust the SITRANS LU10 response to increases in the actual material level (or
advance to a higher Failsafe Material Level, P071).
Enter a value slightly greater than the maximum vessel filling rate.
This value (in Units (P005) or % of Span (P007) per minute) is automatically
altered when Measurement Response (P003) is altered. See
Te ch n ic al
Reference
Measurement Response.
values: 0.000 to 9999
P701 MAX EMPTY RATE
Adjust the SITRANS LU10 response to decreases in the actual material level (or
advance to a lower Failsafe Material Level, P071).
Enter a value slightly greater than the maximum vessel emptying rate.
This value (in Units (P005) or % of Span (P007) per minute) is automatically
altered when Measurement Response (P003) is altered. See
Te ch n ic al
Reference
Measurement Response.
values: 0.000 to 9999
P702 FILLING INDICATOR
Enter the fill rate to activate the LCD Material Filling indicator and Smart Scan
(P720).
This value (in Units (P005) or % of Span (P007) per minute) is automatically set to
10% of the Max Fill Rate (P700).
values: -999 to 9999
P703 EMPTYING INDICATOR
Enter the empty rate to activate the LCD Material Emptying indicator and Smart
Scan (P720).
This value (in Units (P005) or % of Span (P007) per minute) is automatically set to
10% of the Max Empty Rate (P701).
values: -999 to 9999