Page 64 SITRANS LU10 – INSTRUCTION MANUAL 7ML19985AN02
mmmmm
Enhancement Parameters
P805 (V) ECHO CONFIDENCE
Use this feature to monitor the effect of transducer aiming, location, and
mechanical transducer / mounting isolation.
This is the value displayed when is pressed for 4 seconds in the RUN mode.
Both short and long shot Echo Confidence is displayed.
" -- " is displayed if the respective shot (short or long) was not included in the
evaluation.
" E " is displayed if the transducer cable is open or short circuited.
" --:-- " is displayed if no shots have been taken yet.
values: x:y x = short (0 to 99), y = long (0 to 99)
P806 (V) ECHO STRENGTH
Use this feature to view the strength (in dB above 1 µV RMS) of the echo
selected to base the distance calculation upon.
values: 0 to 99
P807 (V) NOISE
Observe the average and peak ambient noise (in dB above 1 µV RMS) being
processed.
The noise level is a combination of transient acoustic noise and electrical noise
(induced into the transducer cable or receiving circuitry itself).
values: x:y x = average (-99 to 99), y = peak (-99 to 99)