Copyright © Sigicom AB 2019
37. Particle displacement
Level, frequency ranges: 250 µm, 1-300 Hz
Max resolution in presentation: 0.1 µm and 3 significant digits.
Threshold range 5-200 µm.
Transient file resolution: ~0.1 µm.
Note! The stated range/resolution in “displacement” is only valid at 16Hz
and below because sensor element measures velocity. At higher
frequencies the range/resolution is scaled down.
38. ÖNORM S 9020
Bauwerkserschütterungen; Sprengerschütterungen und vergleichbare
impulsförmige Immissionen.
Level, frequency ranges: 250 mm/s, 1-315 Hz
Max resolution in presentation: 0.05 mm/s and 3 significant digits.
Threshold range 0.4 – 220 mm/s.
Transient file resolution: ~0.01 mm/s.
39. ÖNORM S 9020
Bauwerkserschütterungen; Sprengerschütterungen und vergleichbare
impulsförmige Immissionen.
Level, frequency ranges: 25 mm/s, 1-315 Hz
Max resolution in presentation: 0.005 mm/s and 3 significant digits.
Threshold range 0.04 – 22 mm/s.
Transient file resolution: ~0.001 mm/s.
40. Arrêté du 1994 (+ Frequency +Weighting)
Arrêté du 22 septembre 1994 relatif aux exploitations de carrières et aux
installations de premier traitement des matériaux de carrières
Level, frequency ranges: 250 mm/s, 1-150 Hz
Max resolution in presentation: 0.05 mm/s and 3 significant digits.
Threshold range 0.4 – 220 mm/s.
Transient file resolution: ~0.01 mm/s.