41. ICPE-Circ86 (+ Frequency +Weighting)
French standard ICPE Circulaire du 23/07/86.
Level, frequency ranges: 25 mm/s, 1-150 Hz
Max resolution in presentation: 0.005 mm/s and 3 significant digits.
Threshold range 0.04 22 mm/s.
Transient file resolution: ~0.001 mm/s.
42. IN 1226 (+ Frequency +Weighting)
French standard IN 1226.
Level, frequency ranges: 250 mm/s, 1-150 Hz
Max resolution in presentation: 0.05 mm/s and 3 significant digits.
Threshold range 0.4 220 mm/s.
Transient file resolution: ~0.01 mm/s.
43. IN 1226 (+ Frequency +Weighting)
French standard IN 1226.
Level, frequency ranges: 25 mm/s, 1-150 Hz
Max resolution in presentation: 0.005 mm/s and 3 significant digits.
Threshold range 0.04 22 mm/s.
Transient file resolution: ~0.001 mm/s.
44. OfM 9/1997
Orientation fra Miljøstyrelsen Nr.9 1997- Lavfrekvent støj, infralyd og
vibrationer i externt miljø.
Level, frequency ranges: 55 - 117 dB (rel. 10
-3
mm/s
2
), RMS, 1-80 Hz
Filtered according to ISO 2631-2, time constant 1 s.
Max resolution in presentation: 0.1 dB and 4 significant digits.
Threshold range: 60-115 dB.
Transient file resolution: 0.04 mm/s2.
45. Turkey Mining and Quarry
Based on the ISEE standard, but in SI units.
Level, frequency ranges: 250 mm/s, 2-250 Hz
Max resolution in presentation: 0.05 mm/s and 3 significant digits.
Threshold range 0.4 220 mm/s.
Transient file resolution: ~0.01 mm/s.