7. Technical Specifications
Enclosure: Aluminum painted gray 146 x 127x 89 mm (5.7 x 5.0 x
3.5 in). Weather proofed by O-rings in all seams.
Weight: Excl. batteries: 1420 g (3.1 lbs.)
Incl. batteries: 1820g (4.0 lbs.)
Memory: 1GB microSD.
Battery: Two Li-Ion 14.4V/3.4Ah/48Wh.
Important! When not in use, store batteries at charge
state < 40% (<14.3V), and at room temperature or
lower.
Expected service lifetime: 3-6 years (70% remaining
charging capacity).
Power Less than 20 mW (in monitoring mode; display and
consumption: communication off).
Run-time: Up to 4 months, depending on ambient temperature,
quantity of transient recordings and scheduled INFRA
Net communications etc.
Backup battery: Expected life > 5 years.
Note! The Backup battery may only be replaced by
Sigicom technician or agent.
Modem: Cellular 2G/3G/4G modem (some variations exist).
Antennas: Adjusted for 900/1800/2100 MHz, for users within EU
and 850/1900/2100 MHz, for users in the US.
Reference Standard: Special cal. standard
conditions: Vibration level: 10 mm/s (0.394 in/s)
Frequency: 80 Hz
Ambient temperature: 23 ºC (73.4 ºF)
Static pressure: 101.3 kPa (14.7 psi)
Accuracy: Noise and interference according to EMC
demands in IEC61326-1:2006.
Transient low-pass filter characteristics:
- 0.5 dB at 467Hz, -3dB at 627Hz.
Operations temp: -20°C to +50°C (-4°F to 122°F)