EasyManuals Logo

Sigicom INFRA C22 User Manual

Sigicom INFRA C22
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
Copyright © Sigicom AB 2021
44
7. Technical Specifications
Enclosure: Aluminum painted gray 146 x 127x 89 mm (5.7 x 5.0 x
3.5 in). Weather proofed by O-rings in all seams.
Weight: Excl. batteries: 1420 g (3.1 lbs.)
Incl. batteries: 1820g (4.0 lbs.)
Memory: 1GB microSD.
Battery: Two Li-Ion 14.4V/3.4Ah/48Wh.
Important! When not in use, store batteries at charge
state < 40% (<14.3V), and at room temperature or
lower.
Expected service lifetime: 3-6 years (70% remaining
charging capacity).
Power Less than 20 mW (in monitoring mode; display and
consumption: communication off).
Run-time: Up to 4 months, depending on ambient temperature,
quantity of transient recordings and scheduled INFRA
Net communications etc.
Backup battery: Expected life > 5 years.
Note! The Backup battery may only be replaced by
Sigicom technician or agent.
Modem: Cellular 2G/3G/4G modem (some variations exist).
Antennas: Adjusted for 900/1800/2100 MHz, for users within EU
and 850/1900/2100 MHz, for users in the US.
Reference Standard: Special cal. standard
conditions: Vibration level: 10 mm/s (0.394 in/s)
Frequency: 80 Hz
Ambient temperature: 23 ºC (73.4 ºF)
Static pressure: 101.3 kPa (14.7 psi)
Accuracy: Noise and interference according to EMC
demands in IEC61326-1:2006.
Transient low-pass filter characteristics:
- 0.5 dB at 467Hz, -3dB at 627Hz.
Operations temp: -20°C to +50°C (-4°F to 122°F)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sigicom INFRA C22 and is the answer not in the manual?

Sigicom INFRA C22 Specifications

General IconGeneral
BrandSigicom
ModelINFRA C22
CategoryMeasuring Instruments
LanguageEnglish