Threshold range: 0.04 15 mm/s.
8. SS 4604861 Komfort
Vibration och stöt Mätning och riktvärden för bedömning av komfort i
byggnader.
Level and frequency ranges: 700 mm/s
2
, RMS, 1-80 Hz.
Filtered according to ISO 2631-2,
time constant 1 s.
Max resolution in presentation: 0.1 mm/s
2
RMS and 3 significant digits.
Threshold range: 1 550 mm/s
2
.
9. DIN 4150-2 KB
Erschütterungen im Bauwesen Teil 2: Einwirkungen auf Menschen in
Gebäuden.
Level and frequency ranges: 20 mm/s, RMS, 1-80 Hz.
Filtered according to ISO 2631-2,
time constant 125 ms.
Max resolution in presentation: 0.005 mm/s RMS and 3 significant
digits.
Threshold range: 0.04 15 mm/s.
15. ÖNORM S 9012
Beurteilung der Einwirkung von Schwingungsimmissionen des
landgebundenen Verkehrs auf den Menschen in Gebäuden ―
Schwingungen und sekundärer Luftschall.
Level and frequency ranges: 700 mm/s
2
, RMS, 1-80 Hz.
Filtered according to ISO 2631-2,
time constant 1 s.
Max resolution in presentation: 0.1 mm/s
2
RMS and 3 significant digits.
Threshold range: 1 550 mm/s
2
.
16A. ISO 8569 Acceleration
Mechanical vibration and shock Measurement and evaluation of shock
and vibration effects on sensitive equipment in buildings.
Level and frequency ranges: 125 m/s
2
, 5-300 Hz.
Max resolution in presentation: 0.01 m/s
2
and 3 significant digits.
Threshold range: 0.1 110 m/s
2
.
Note! The stated level range is only valid at 80Hz because the sensor