SDS Series
23
Current Water %
100%
VIEW PROGRAMMING STATUS:
To check programs status press “0” at the current Time and Date display. You will see “A”
displayed beneath the program you have just completed. See page 22.
QUICK START PROGRAMMING:
For a basic time based program running one pump or master valve with the correct current
time and date already set on the controller - Follow the easy step by step guide below to get
started:
A basic program is now entered to run on a time basis. The pump/master valve number is 49
(default). No delays between stations have been set. No auxiliary/chemical injection program
has been set to run. The program was not optioned for looping so it will start at the pro-
grammed times and finish at the end of the last station run time in a program. All default set-
tings have been used.
From the current Time
and Date display scroll
PROGRAM
< Press Enter >
Select program
number
< P# Mode >
Normal
P# Master Pump
Default
P# Water Days
SMTWTFS SMTWTFS
< P# Start time# >
00 : 00 : 00 Am
Use < > keys
to select days
To return to the Time and Date dis-
play hold the Back key down
Use < > keys to
advance more stns
<P# Option >
Time
<P# WaterStn 01
00 : 00 : 00 100%
Enter run times with nu-
meric keys Hr:min:sec
Or
copy run times
to next stns
MANUALLY START & STOP PROGRAMS:
From the current Time
and Date display scroll
MANUAL/TEST
< Press Enter >
Manual Start Prg
< Press Enter >
Enter Program
1
Program Type
< Normal Program >
Select program
number
Program %[0-250]
100
To stop
program
Quick Start Programming
< P1 Start Time 1 >
NONE
Enter time and
select AM/PM
Use < > keys for
additional starts
P# station Delay
00 Secc (0-30)
P# Total Water
00:00:00
Start Time Overlap
NONE
Select program
number
P1 Day Options
NONE