6.13.3 ALARM MESSAGES
This message indicates that there is a fault in the optical reader or that something is obstructing its laser beam
before starting the reading or decoding cycle.
The electronic control board has exceeded the maximum permitted temperature. Check the cooling fan (SEE
Ch.8.1 "Trouble shooting", page 73).
Indicates that the fuse has blown due to a short circuit in an inlet or outlet (see Ch.8.1 "Trouble shooting", page
73).
Indicates a short circuit in port P (IN/OUT) (see Ch.8.1 "Trouble shooting", page 73).
Indicates that the fuse has probably blown (see Ch.8.1 "Trouble shooting", page 73).
Indicates a fault on the electronic control board.
This message appears when the machine detects an unexpected contact.
This message appears when gauging a clamp that requires the previous gauging of the standard V100 clamp.
ALARM 1
OPTICAL READER
E R R O R
See operating manual
ALARM 2
TEMPERATURE ALARM
Turn the machine off!
ALARM 3
I/O POWER ALARM
Check fuse F4!
ALARM 4
DIGITAL OUTLET
PROTECTION ALARM
Turn the machine off!
ALARM 5
CUTTER MOTOR
ALARM
Check fuse F1!
ALARM 6
CUTTER MOTOR
Fault on motor circuit!
Faulty contact made!