UNOCODE PRO Operating manual - English
58 Copyright Silca 2017
6.10.9 PHOTOCELLS AND SENSORS REGULATION
PRELIMINARY OPERATIONS
1)
turn the machine off and unplug it from its power supply cable
.
2) remove the back panel
(Ch.8.8).
3) loosen the (G1) and (G2) grub screws that secure the X axis photocell disk (fig. 34).
4) remove the bottom panel (Ch.8.9).
5) disconnect the (J1) Y axis cable from the carriage (fig. 35).
6) unscrew the 3 (B5) fixing screws and remove the Y axis protective cover by pulling it in the direction shown in fig.
36.
7) plug the Y axis (J1) cable.
8) turn the machine on and carry on with the procedures described on
page 59 .
Fig. 34
Fig. 35
- the machine will take the X and Y axes to a predefined position.
- the operator must manually rotate the X and Y photocell disks up until the cut in the disks face the photocells card.
G1 G2
X axis
X axis
photocell disk
photocell
X axis
photocell disk
X axis
photocell
card
Y axis photocell
Y axis sensor
Y axis photocell disk
B5
J1

Table of Contents