1.5 Fault / malfunction codes
If a fault/malfunction is detected during boiler operation, the
message
"AL"
will appear on the display followed by the fault
code.
If you see alarm
“02”
(low water pressure in the system):
press the button
>
(bar)
to view the value pression on the
display or using the pressure gauge (1) check that the pres-
sure in the heating system, when cold, is
1-1.2 bar
. If the
pressure is less than this, use the external filling device to
repressurise the system to
1-1.2 bar
ensure that the filling device is turned off after use
press and hold the
o
R
button for more than 3 seconds
and check whether normal operating conditions are re-
stored.
1
Fig. 5
If you see alarm
“06”
(no flame detected) and
“07”
(safety ther-
mostat intervention):
press and hold the
o
R
button for more than 3 seconds
and check whether normal operating conditions are re-
stored.
If this operation is not successful,
ONLY ONE MORE ATTEMPT
can be made, therefore:
close the gas cock
isolate the power supply
contact the Qualified Technical Personnel.
OFF
Fig. 6
m
CAUTION
Should you see an alarm not described here, contact a
qualified technical professional
2 SHUTDOWN
2.1 Temporary shutdown
To temporarily interupt the boiler operation press and hold the
button
s
for at least one second, once if in "WINTER mode"
n
or twice if in "SUMMER mode"
l
.
"- -"
will appear on the
display the boiler will be in STAND-BY. The boiler anti freeze
function will be enabled.
f
ELECTRICAL HAZARD
The boiler will still be powered.
If the user is away temporarily, for a weekend, short trip etc
and if the outside temperature is at ZERO:
press and hold the button
s
once if in "WINTER mode"
n
or twice if in "SUMMER mode"
l
to put the boiler into
stand-by
isolate the power supply
isolate the gas cock.
OFF
Fig. 7
m
CAUTION
If the outside temperature might fall below ZERO,
since the appliance is equipped with an "antifreeze
function"
ONLY PUT THE BOILER INTO STAND-BY
leave the main system switch set to "ON" (boiler
is powered)
leave the gas cock open.
2.2 Shutting down for long periods
If the boiler is to be left unused for a long period, the following
operations need to be carried out:
press and hold the button
s
for at least 1 second, once if in
"WINTER mode"
n
or twice if in "SUMMER mode"
l
to
put the boiler into stand-by
"- -"
will appear on the display

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sime GIULIA SYSTEM 25 and is the answer not in the manual?

Sime GIULIA SYSTEM 25 Specifications

General IconGeneral
BrandSime
ModelGIULIA SYSTEM 25
CategoryBoiler
LanguageEnglish

Related product manuals