"Input receipt short"
(at all LockNodes)
The output switches when the response (see
RouterNode: Di-
gital input [}77]
) to a signal at the corresponding input on all
LockNodes has been performed (=input event) for about one
second.
"Input receipt static"
(at all LockNodes)
The output switches when the response (see
RouterNode: Di-
gital input [}77]
) to a signal at the corresponding input has
been performed on all LockNodes. As long as the input event is
present after the response is completed, the output remains
switched.
Output 1 O1
Relay output, consisting of O1.NC, O1.NO and
O1.COM
NC=Normally connected, is connected to COM in
idle state.
NO=Normally open, is not connected to COM in
idle state.
When the output is switched, the relay picks up and
changes from the idle state to the energized state.
Output 2 O2
Digital output (Open Drain), max. 12 V
DC
, max. 100
mA (resistive load)
When the output is switched, the output is connec-
ted to the ground potential.
Output 3 O3
Digital output (Open Drain), max. 12 V
DC
, max. 100
mA (resistive load)
When the output is switched, the output is connec-
ted to the ground potential.
With the button Select LN you can open the window "Select LN to
configure I/O settings". Select the LockNodes in locking devices here.
Authorised access or unauthorised access attempts at these locks
(LockNodes) are forwarded to the LSM.
WaveNet (Manual)
5. WaveNet Manager
75 / 210