94 |
Appendix A | V5035 Operator and Installation Manual
Supported IEC 61162 Data sentences
Data Port Input sentences Output sentences
Sensor 1
Sensor 2
Sensor 3
DTM, GBS, GGA, GLL, GNS, GSA, HDG,
HDT, OSD, RMC, ROT, THS, VBW, VHW,
VTG
N/A
DGPS
DTM, GBS, GGA, GLL, GNS, GSA, HDG,
HDT, OSD, RMC, ROT, THS, VBW, VHW,
VTG
N/A
External Display
ABM, ACA, ACK, AIQ, AIR, BBM, EPV,
LRF, LRI, SSD, SPW, VSD
ABK, ACA, ALR, EPV, LR1, LR2,
LR3, LRF, TXT, VDM, VDO
Pilot
ABM, ACA, ACK, AIQ, AIR, BBM, EPV,
LRF, LRI, SSD, SPW, VSD
ABK, ACA, ALR, EPV, LR1, LR2,
LR3, LRF, TXT, VDM, VDO
Long Range LRF, LRI LR1, LR2, LR3, LRF
Transmission interval
Sentence Interval
VDO Once a second
ALR (active) Once every thirty seconds
ALR (inactive) Once every sixty seconds
Interpretation of Input Sentences
ABM – AIS Addressed Binary and Safety Related Message
This sentence supports ITU-R M.1371 Messages 6, 12, 25, 26 and
provides an external application with a means to exchange data via
an AIS transponder.
!--ABM,x,x,x,xxxxxxxxx,x,xx,s—s,x*hh<CR><LF>
Field No. Format Description Remark
1 x
Total number of sentences needed to transfer the
message
2 x Sentence number
3 x Sequential message identifier
4 xxxxxxxxx
The MMSI of the destination AIS unit for the ITU-R
M.1371 message