User Manual
EM100 Mini Inverter
118
Appendix Table 1
Control Command 1 (4000H)
Data Meaning Data Meaning
0000H Inactive Command 0006H Ramp to Stop
0001H Forward Running 0007H Coast to Stop
0002H Reverse Running 0008H Fault Reset
0003H FJOG 0009H +/- Input Switch
0004H RJOG 000AH Not Used
0005H Slave-inverter Stops 000BH Not Used
Inverter Status 1(4100H):
Data Meaning Data Meaning
0000H Parameter Setting 0004H Slave-inverter Stops
0001H Slave-inverter Runs 0005H JOG Stop
0002H JOG Running 0006H Fault Status
0003H Autotuning 0007H Factory Check