SCISSOR ARMS COMPONENTS
0608ME All Maintenance Manual 31
© Jan. 2024
time. But the spot inspection should be carried out
every 1.5 months or every 125 hours.
• If the drive current is equal to or higer than (1+20%)
normal current, it means that the screw and nut of lift
electric actuator have worn out, and at this time, the
platform lifting will be disabled, but platform lowering
will be allowed.