CONTROL SYSTEM
0608ME All Maintenance Manual 61
© Jan. 2024
The setting value of low voltage alarm time is in sec-
onds (s); the setting value of the standby time is in
minutes (min).
System Parameters
In the System Parameters menu of Parameter Debug-
ging, the following can be set: up and down limit
switches, pothole protection switch, lowering delay
switch, car tilt detection, outdoor mode configuration,
weighing device, angle sensor, level inclination switch,
function keys, level angle sensor, pothole guard speed
limit, standby function, dual pressure configuration, sin-
gle pressure configuration, lowering overload limit, horn
configuration, GPRS communication configuration, foot
switch configuration, anti-collision switch configuration,
80/90 overweight alarm and vehicle tilt detection.
Motion Parameters
In the Motion Parameters menu of Parameter Debug-
ging, the speed parameters of lifting motion, lowering
motion, steering motion, raised travel speed, high speed
(stowed) and low speed (stowed) can be set.