Section 5 – Operation Start Operation
5.1-26 Arctic weather package (if
equipped)
WARNING
▪
Do not use heaters if temperature is above
freezing.
▪
Use the correct uids, and the proper diesel
fuel (refer to Cold Weather Operation Chart).
▪
At temperatures below -7°C (20°F), run engine
at idle for at least 5 minutes before operating
MEWP.
1. Ensure the MEWP is on level ground, boom
is in stowed position and hydraulic oil level is
between the minimum and maximum marks on
the sight gauge.
2. Locate heater plug (item
1
- Figure 23) in
engine compartment.
3. Plug heater into a 110V / 15 Amp protected
circuit for a minimum of 4 hours.
4. Start engine from base control console (refer to
Section 5.1-1).
WARNING
DO NOT over crank the starter. If engine fails to
start after multiple attempts, contact a Service
Technician.
IMPORTANT
Ensure the heater is unplugged before operating
the MEWP.
NOTE
▪
If the MEWP is to be parked for an extended
period of time, remove the battery and store it
in a warm place.
▪
Refer to the cold weather operation chart
(Figure 24) to assist in operating the MEWP in
cold weather conditions.
Figure 24 Heater plug
30° F (- 1° C)
20° F (- 7° C)
10° F (- 12° C)
0° F (- 18° C)
- 10° F (- 23° C)
- 20° F (- 29° C)
- 30° F (- 34° C)
- 40° F (- 40° C)
40° F (4° C)
NO OPERATION BELOW THIS
TEMPERATURE
USE COLD START KIT WITH TANK
HEATER AND BATTERY WARMER
BELOW THIS TEMPERATURE
SAE 5W-30
NO OPERATION BELOW THIS
TEMPERATURE
- 40° F (- 40° C)
30° F (- 1° C)
20° F (- 7° C)
10° F (-12° C)
0° F (- 18° C)
- 10° F (- 23° C)
- 20° F (- 29° C)
- 30° F (- 34° C)
40° F (4° C)
ENGINE OIL
SPECIFICATION
SAE 15W-40
HYDRAULIC OIL
SPECIFICATION
UNIVIS HVI 26
Shell Tellus T46
SAE 5W-30
SAE 0W-40
(DIESEL)(DUAL FUEL)
Figure 25 Cold weather operation chart