Parameter Lists SMA Technologie AG
Page 130 SI5048-11:EE4206 Technical Description
#221 05 BatTmpStr degC 35 battery restart temperature following
stop due to overtemperature
#222 Battery Charge Mode
#222 01 BatChrgCurMax A 1200 battery charging current limit
(depends on nominal battery
capacity)
#222 02 AptTmBoost min 120 absorption time for normal charge
120 = VRLA
90 = FLA
300 = NiCd
depending on the setting in QCG
#222 03 AptTmFul h 5 absorption time for full charge
5 = VRLA
5 = FLA
7 = NiCd
depending on the setting in QCG
#222 04 AptTmEqu h 10 absorption time for equalization
charge
10 = VRL A
10 = FLA
10 = NiCd
depending on the setting in QCG
#222 05 CycTmFul d 14 full charge cycle time
#222 06 CycTmEqu d 180 equalization charge cycle time
#222 07 ChrgVtgBoost V 2.4 cell voltage nominal value for normal
charge
2.4 = VRLA
2.55 = FLA
1.65 = NiCd
depending on the setting in QCG
#222 08 ChrgVtgFul V 2.4 cell voltage nominal value for full
charge
2.4 = VRLA
2.5 = FLA
1.65 = NiCd
depending on the setting in QCG
#222 09 ChrgVtgEqu V 2.4 cell voltage nominal value for
equalization charge
2.4 = VRLA
2.5 = FLA
1.65 = NiCd
depending on the setting in QCG
#222 10 ChrgVtgFlo V 2.25 cell voltage nominal value for float
charge
2.25 = VRLA
2.25 = FLA
1.55 = NiCd
depending on the setting in QCG
Menu
no.
Para-
meter
no.
Parameter name Range/
Short
descr.
Default
value
Description