SMA Sunny Island 5048 Specifications

General IconGeneral
Output Voltage230 V
Nominal AC Voltage230 V
AC Frequency50 / 60 Hz
DC voltage range40 - 60 V
Battery Voltage48 V
Efficiency95 % (typical)
Weight40 kg
Protection classIP 21
Maximum AC Output Power5000 W
Maximum Efficiency96 %
Dimensions (H x W x D)550 x 450 x 230 mm
Operating temperature range-25 °C to +60 °C

Summary

The Sunny Island 5048

2.1 Properties

Details the key features and capabilities of the Sunny Island 5048 inverter.

2.2 At a Glance

Provides an overview of the device's control elements and connections.

2.4 Scope of Delivery

Lists the components included in the product package.

Electrical Connection

6.1 Grounding

Describes essential grounding procedures for safe installation and operation.

6.2 DC Connection

Details the procedures and safety precautions for connecting the DC side.

6.3 AC Connection

Explains the AC connection requirements and steps for different configurations.

Activation and Deactivation

9.1 Activation / Startup

Details the procedure for starting up and activating the Sunny Island 5048.

Operation

10.1 Menu Structure

Presents the hierarchical structure of the device's menus and submenus.

10.5 Entering the Installer Password

Explains how to access and use the installer password for system settings.

Battery Management

13.1 Battery Temperature

Details battery temperature monitoring and its impact on operation.

13.3 State of Charge/SOC and SOH

Explains how battery charge and health states are calculated and displayed.

13.4 Charge Control

Describes the different charging phases and processes for battery management.

Connecting External Sources

14.1 Generator

Details the integration and operation of generators with the Sunny Island 5048.

14.2 Grid

Covers the operation and connection of the Sunny Island 5048 with the public grid.

Troubleshooting/Problem Solving

19.1 Error Categories

Classifies errors into levels with corresponding device behaviors and user actions.

19.9 Troubleshooting

Provides solutions for common problems and questions encountered during operation.

Technical Data

Related product manuals