-84-
No.PF※※-OMY0005
●Product individual parameters (continued)
AC_1ot
(Selection of output
type)
0: 1_P (Normal output)
1: 1_n (Reverse output)
P1(n1)_L
(Selection of output
set value)
Common for all ranges, units, and
criterion
P1(n1)_ft3
(Selection of output
set value)
Common for all ranges, units, and
criterion
0: 10 (L/pulse)
1: 100 (L/pulse)
OUT1 accumulated pulse converted
value setting
1000 L range
0: 0.1 (L/pulse)
1: 1(L/pulse)
2000 L range
0: 1 (Ft
3
/pulse)
1: 10 (Ft
3
/pulse)
1ot
(Selection of output
type)
0: 1_P (Normal output)
1: 1_n (Reverse output)
Setting of OUT1 output normal and
reserved output.
OUT2
(Select the target for
setting)
0: FLoW (Flow rate)
1: Temp (Temperature)
2: PrES (Pressure)
3: AC (Accumulated)
4: PLS
(Accumulated pulse)
5: Err (Error output)
6: oFF (Output OFF)
ModE2
(Selection of output
mode)
0: HYS (Hysteresis)
1: Wind
(Window comparator)
2ot
(Selection of output
type)
0: 1_P (Normal output)
1: 1_n (Reverse output)
Setting of OUT2 output normal and
reserved output
P_2 (n_2)
(Selection of output
set value)
Setting range
0x0028 to 0x1068
(40 to 4200)
Setting of OUT2 output set value
(Hysteresis)
H_2
(Setting of OUT1
hysteresis)
Setting range
0x0000 to 0x1040
(0 to 4160)
Setting of OUT2 hysteresis
(Hysteresis)
P2L (n2L)
(Lower limit of window
comparator)
Setting range
0x0028 to 0x1068
(40 to 4200)
Setting of OUT2 output set value
(Lower limit of window comparator)
P2H (n2H)
(Upper limit of window
comparator)
Setting range
0x0028 to 0x1068
(40 to 4200)
Setting of OUT2 output set value
(Upper limit of window comparator)
WH2
(Window comparator
hysteresis)
Setting range
0x0000 to 0x0820
(0 to 2080)
Setting of OUT2 hysteresis
(Window comparator)
Setting range
0x0000 to 0x1770
(0 to 6000)
Setting of OUT2 delay time ON
10 ms increments
Setting of OUT2 delay time OFF
10 ms increments