Names and Functions of Product
Names of individual parts
Indication light (Orange light): Displays switch operation condition.
LCD display: Displays the current status of pressure, setting mode, selected indication unit and error code.
Four display modes can be selected: display always in red or green only, or changing from
green to red linked to output.
button (UP): Selects the mode or increases ON/OFF set value.
Press this button to change to the peak display mode.
button (DOWN): Selects the mode or decreases ON/OFF set value.
Press this button to change to the bottom display mode.
button (SET): Press this button to change to either mode and to set a set value.