PROBLEM 1: Cooling fin overtemperature
Solution:
Check the board heatsink cooling fan
Check that the electrical panel air intakes are not obstructed
If the problem continues, switch power off and contact the service centre.
PROBLEM 2: Temperature reading outside the set limits.
Solution:
Check the thermocouple operation
Check the thermocouple linking cable
Check connection cable
If the problem continues, switch power off and contact the service centre.
PROBLEM 5: Problem with the closed micro pusher.
Solution:
Check the micro operation (SQ4) or decrease the pusher speed.
Check the pneumatic circuit pressure
Check the cylinder operation
If the problem continues, switch power off and contact the service centre.
PROBLEM 7: Incorrect configuration.
Solution:
Re-set the machine model from menu reserved to re-program the board
If the problem continues, switch power off and contact the service centre.
PROBLEM 8: Data reading problem
Solution:
A problem with the microprocessor has occurred, therefore the board must be changed
PROBLEM 9: The sealing bar end stop has not been detected
Solution:
If the sealing bar does not move:
Check the pneumatic circuit pressure
Check the cylinder proper movement in the absence of pneumatic air and with the system off
Check 24V circuit fuse on board
Check electrovalve connection (YV1)
Check soldering bar sensor operation (SQ2)
If the problem continues, switch power off and contact the service centre.
PROBLEM 10: Output overload 24V.
Solution:
Disconnect power and check the low voltage circuit for possible short circuits or
malfunctioning of any component;
If the problem continues, switch power off and contact the service centre.