WARNING!
When you turn ON the inverter ON/OFF/P switch, the DC cables carry a high
voltage and the power optimizers no longer output a safe output.
AVERTISSEMENT!
Après avoir mis l'interrupteur ON/OFF/P de l'onduleur monophasé sur ON,
les câbles DC portent une haute tension et les optimiseurs de puissance ne
génèrent plus la tension de sécurité de .
When the inverter starts converting power after the initial connection to the AC, the
inverter enters Wakeup mode until its working voltage is reached. This mode is
indicated by the flickering green inverter LED.
When working voltage is reached, the inverter enters Production mode and
produces power. The steadily lit green inverter LED indicates this mode.
4. Tap OK to return to the main menu.
Communication
Communication settings can be configured only after communication connections are
complete. Refer to
Setting Up Communication to the Monitoring Platform
on page 58.
1.
Select the Communication menu to define and configure the following:
The communication option used by the inverter to communicate with the
monitoring platform.
The communication option used to communicate between multiple SolarEdge
devices or other external non-SolarEdge devices, such as electricity meters or
loggers.
2.
Tap the Server red arrow to set the communication method to be used for
communication between devices and the SolarEdge monitoring platform. The
default is LAN.
NOTE
The Server menu shows only the communication options installed in the
inverter.
For detailed information about all the configuration options, refer to the
Communication Options Application Note
, available on the SolarEdge
website at https://www.solaredge.com/sites/default/files/solaredge-
communication_options_application_note_v2_250_and_above.pdf.
Chapter 4: Activating, Commissioning and Configuring the System 45
EV Charging Single Phase Inverter Guide MAN-01-00588-1.1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge EV Series and is the answer not in the manual?

SolarEdge EV Series Specifications

General IconGeneral
AC Frequency60 Hz
Protection RatingIP65
AC Voltage208/240 V
EV Charger Output Voltage208/240 V
EV Charger Max. Output Current32 A
CommunicationEthernet, Wi-Fi
SafetyUL1741
Operating Temperature Range-25°C to 60°C