Date and Time: Set the internal real-time clock. If connected to the monitoring
platform, the date and time are set automatically and only time zone should be
set.
Reset Counters: Resets the accumulated energy counters that are sent to the
monitoring platform
Factory Reset: Performs a general reset to the default device settings.
Arc Fault Circuit Interrupter (AFCI): Enables or disables production interruption
in case of arc-fault, sets the reconnection mode, and enables or disables manual
AFCIself-test.
Refer to https://www.solaredge.com/sites/default/files/arc_fault_
detection_application_note.pdf .
Firmware Upgrade: Perform a software upgrade.
Diagnostics: Displays the Isolation status and power optimizer
status screens. Refer to
https://www.solaredge.com/sites/default/files/application_note_
isolation_fault_troubleshooting.pdf.
Activate Standby Mode: Enables/disables Standby Mode - for
remote commissioning.
Grid Protection: Available in specific countries. Enables viewing and setting grid
protection values.
Board Replacement: Backs up and restores the system parameters, including
energy counters; Used during board replacement according to the instructions
supplied with replacement kits.
Information
From the Commissioning menu, select Information to view and set various system
settings, as described below.
CPU Version: The communication board firmware version
DSP 1/2 Version: The digital board firmware version
NOTE
Please have these numbers ready when you contact SolarEdge Support.
Serial Number - The inverter serial number as appears on the enclosure sticker
Chapter 5: Activating, Commissioning and Configuring the System Using the
Inverter SetApp 39
Three Phase System Installation Guide MAN-01-00505-1.2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE5K and is the answer not in the manual?

SolarEdge SE5K Specifications

General IconGeneral
ModelSE5K
ManufacturerSolarEdge
AC Output Power5000 W
Rated AC Power5000 W
Max. Efficiency98.3%
CoolingNatural convection
Protection RatingIP65
Max. Input DC Voltage480 V
Max. Input Current11 A
Number of MPP Trackers1
Warranty12 years
Communication InterfacesRS485, Ethernet
AC Voltage230 V
Operating Temperature Range-25°C to +60°C
MPPT Voltage Range330-480V