HANDLING AND SAFETY INSTRUCTIONS
During installation, testing and inspection, adherence to all the handling and safety
instructions is mandatory. Failure to do so may result in injury or loss of life and
damage to the equipment.
Safety Symbols Information
The following safety symbols are used in this document. Familiarize yourself with the
symbols and their meaning before installing or operating the system.
WARNING!
Denotes a hazard. It calls attention to a procedure that, if not correctly
performed or adhered to, could result in injury or loss of life. Do not proceed
beyond a warning note until the indicated conditions are fully understood and
met.
CAUTION!
Denotes a hazard. It calls attention to a procedure that, if not correctly
performed or adhered to, could result in damage or destruction of the
product. Do not proceed beyond a caution sign until the indicated conditions
are fully understood and met.
NOTE
Denotes additional information about the current subject.
IMPORTANTSAFETYFEATURE
Denotes information about safety issues.
Disposal requirements under the Waste Electrical and Electronic Equipment (WEEE)
regulations:
NOTE
Discard this product according to local regulations or send it back to SolarEdge.
HANDLING AND SAFETY INSTRUCTIONS 7
Three Phase System Installation Guide MAN-01-00505-1.2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE5K and is the answer not in the manual?

SolarEdge SE5K Specifications

General IconGeneral
ModelSE5K
ManufacturerSolarEdge
AC Output Power5000 W
Rated AC Power5000 W
Max. Efficiency98.3%
CoolingNatural convection
Protection RatingIP65
Max. Input DC Voltage480 V
Max. Input Current11 A
Number of MPP Trackers1
Warranty12 years
Communication InterfacesRS485, Ethernet
AC Voltage230 V
Operating Temperature Range-25°C to +60°C
MPPT Voltage Range330-480V