Hardware IDs: Displays the following HW serial numbers (if exist, and
connected to the inverter):
This inverter: the inverter's ID
Meter # : Energy meter ID (up to 3 meters can be connected)
ZB: ZigBee Plug-in MAC address
WiFi: Wi-Fi MAC address
Error Log: Displays the last five errors, and enables resetting (clearing) the log.
Warning Log: Displays the last five warnings, and enables resetting (clearing)
the log.
Step 3: Verifying Proper Activation and
Commissioning
1. Select Information and verify that the correct firmware versions are installed on each
inverter.
2. Select Status and verify that inverter is operating and producing power (see also
Viewing System Status
on page 40).
3. Verify that additional configurations were properly set by viewing the relevant
Status screens.
4. Verify that the green inverter LEDis steadily lit.
Your SolarEdge power harvesting system is now operational.
Viewing System Status
During normal operation, the Status screen displays all the inverter settings and
operation status. Scroll up or down to display various status parameters as described in
the following sections.
The LED indication provides more information about system performance; Refer to
LEDs
on page 22.
To access the Status screen:
From the Commissioning menu select Status. The main inverter Status screen is
displayed (see below).
A red or orange icon (for example: ) may appear at the top left corner of a status cell,
indicating an error. The color indicates error severity (red is top severity). The error
description or information appears on the screen. Tap the error line for more
information and troubleshooting instructions, and refer to
Errors and Troubleshooting
on page 62.
-Three Phase System Installation Guide MAN-01-00505-1.2
40 Step 3: Verifying Proper Activation and Commissioning

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE5K and is the answer not in the manual?

SolarEdge SE5K Specifications

General IconGeneral
ModelSE5K
ManufacturerSolarEdge
AC Output Power5000 W
Rated AC Power5000 W
Max. Efficiency98.3%
CoolingNatural convection
Protection RatingIP65
Max. Input DC Voltage480 V
Max. Input Current11 A
Number of MPP Trackers1
Warranty12 years
Communication InterfacesRS485, Ethernet
AC Voltage230 V
Operating Temperature Range-25°C to +60°C
MPPT Voltage Range330-480V