Server Communication Status
S e r v e r : L A N < S _ O K >
S t a t u s : <OK>
x x x x x x x x
< E R R O R M E S S A G E >
Server: The method of connection to the SolarEdge monitoring portal
S_OK: The connection to the SolarEdge monitoring portal is successful (should appear only if the
inverter is connected to the server).
Status: Displays OK if the inverter established a successful connection and communication with the
specified server port/device (LAN, RS485 or ZigBee module).
xxxxxxxx: Eight-bit Ethernet communication connection status: A string of 1s and 0s is displayed.
1 indicates OK, 0 indicates an error. For a list of the possible errors and how to troubleshoot them,
refer to Troubleshooting Communication on page 50.
Error message, according to failure
Refer to Troubleshooting Communication on page 50 for detailed information.
IP Status
This window describes the Ethernet configuration: IP, Mask, Gateway and MAC address (Media Access
Control) of the inverter.
I P 1 9 2 . 1 6 8 . 2 . 1 1 9
M S K 2 5 5 . 2 5 5 . 2 5 5 . 0
G W 1 9 2 . 1 6 8 . 2 . 1
M A C 0 - 27- 02- 00- 39- 36
ZigBee Status
This window describes the ZigBee configuration:
PAN: X X X X X
C h : X X / X X X X R S S I : < L >
ID:X X X X X X X X
M I D : X X X X X X
RSSI: The receive signal strength indication of the closest ZigBee in the SolarEdge system. L = low,
M = medium, H = high and (-) = no signal.
PAN ID: The ZigBee transceiver pan ID
Ch.: The ZigBee transceiver channel
ID: The ZigBee transceiver ID
MID: The Master ID of the coordinator (master) ZigBee module. This field is shown only in devices
with router (slave) ZigBee modules. This field appears after a successful ZigBee association. If a
ZigBee module is not connected, a No ZigBee message is displayed instead of the MID field.